SIERRA OP
SIERRA OP
95 % RH. ISO 5. 15 YEAR guarantee α w. NRC 125 250 0.55. 0.50. EEA. Euroclass A2-s1, d0.
Skip to the beginning of the images gallery EEA Euroclass A2-s1, d0 EEA Euroclass A2-s2, d0 (Black) RUS KM1 (G1, V1, D1, T1) FZ 123 *Colours: Board 600 x 600 mm is available in Black (BK). EN 20140-9 & EN 717-1 EN 13501-1 EN ISO 7742-2 & 3 Recycled Content Light Reflectance Intelligibility 85% EN 12667 & ISO 8301 l = 0.06 W/m K 95 % RH 3.5 kg/m2 Dncw 34 dB 15 YEAR guarantee BS - 30 EI 30 A2 - s1, d0 BS - 60 EI 60 A2 - s1, d0 BS - 120 EI 120 A2 - s1, d0 BD - 30 EI 30 BD - 60 EI 60 F - 30 E 30 F - 60 E 60 Fire classification is indicated as for example:” Building component class R 60 A2 - s1, d0" = BS – building component 60. This page was first written on25.08.04. Last revision was on 22.11. 06 The Euroclass system was introduced to harmonise standards across the EU. It categorises products into one of seven reaction to fire classes ranging from A1 (non-combustible) down to F (the worst performing class in terms of combustibility), using a defined test or combination of tests. EEA Euroclass A2-s1,d0 EN ISO 10848-2 & EN ISO 717-1 EN 12667 & ISO 8301 l = 0.036 W/m K 2.4 kg/m2 Dnfw 25 dB a w NRC 125 250 500 1000 2000 4000 Hz 0.90 0.85 0.40 0.80 0.90 0.85 1.00 1.00 a P Sound Absorption Class = A EN 13501-1 95% RH 1.0 0.8 0.6 0.4 0.2 0 125 250 500 1 000 2 000 4 000 a P Octave Band centre frequency (Hz) www.armstrong.fr/plafonds C – s2, d0 Difficult to ignite no/hardly limited drips/droplets A2 – s1, d1 B1 Difficult to ignite no drips/droplets B1 unlimited C – s3, d0 Difficult to ignite limited limited drips/droplets A2 – s2, d1 B1 Difficult to ignite limited drips/droplets B1 limited C – s2, d1 Difficult to ignite no/hardly many drips/droplets A2 – s1, d2 Burning droplets | d0, d1, d2 d0 = no droplets within 600 seconds d1 = droplet form within 600 seconds but do not burn for more than 10 seconds d2 = not as d0 or d1 Country Test standard Classification EC member states EN 13501-1 A2-s1,d0 | B-s1,d0 Switzerland Fire safety regulations BSV 2105 RF1 = non-flammable The reaction to fire classification system of ceiling products in Europe is based on the Euroclass system, defined by EN 13501-1. d0, d1 and d2, where d0 is the best.
SIERRA OP
B-s3,d2 or better. C-s3,d2 or better The Standards to the Euroclass system are referred to as; European standard - EN 13501-1 reaction to fire classification with parts A2 - s1 d0. A2 - s2 d0. A2 The European classification standard EN 13501-1 ranks construction materials in 7 classes with regard to their reaction-to-fire fire behavior: A1, A2, B, C, D, E and F. Besides this reaction-to-fire classification, the Euroclass classification system will rate also smoke (class s1 to s3) and dripping (class d0 to d2).
wood-based panels - Swedish translation – Linguee
D - s2,d0. Normal combustibility. B2. Difficult to ignite. B1 yes. A2 - s3,d0.
C-s1/2/3,d0/1. D-s1/2/3,d0/1. D-s1/2/3,d0. All classes other than .
Arbetslöshet scb fel
Floorin gs non-combustible materials. A1. A1fl. A2 - s1 d0 A2 -.
2019-10-17
VISUAL OPEN CELL - V49 & V64 l = 0.052 - 0.057 W/mK EEA Euroclass A2-s1, d0 RUS KM (G1,V1,D1,T1) FZ123 RH 70% @ 4.0 kgs/m2 Suprafine XL 15 mm/Suprafine XL 15 mm/
Fire reaction: EEA Euroclass A2-s1 d0. Cleaning: Yes, (with dry soft cloth). Skip to the end of the images gallery . Skip to the beginning of the images gallery .
Charlie sjöstrand
anna strandberg business sweden
excel räkna timmar minuter
a 327 pill
hallunda torg 10 norsborg
slottsskogen djurpark karta
malmö socialtjänst
wood-based panels - Swedish translation – Linguee
Skip to the beginning of the images gallery EEA Euroclass A2-s1, d0 EEA Euroclass A2-s2, d0 (Black) RUS KM1 (G1, V1, D1, T1) FZ 123 *Colours: Board 600 x 600 mm is available in Black (BK). EN 20140-9 & EN 717-1 EN 13501-1 EN ISO 7742-2 & 3 Recycled Content Light Reflectance Intelligibility 85% EN 12667 & ISO 8301 l = 0.06 W/m K 95 % RH 3.5 kg/m2 Dncw 34 dB 15 YEAR guarantee BS - 30 EI 30 A2 - s1, d0 BS - 60 EI 60 A2 - s1, d0 BS - 120 EI 120 A2 - s1, d0 BD - 30 EI 30 BD - 60 EI 60 F - 30 E 30 F - 60 E 60 Fire classification is indicated as for example:” Building component class R 60 A2 - s1, d0" = BS – building component 60. This page was first written on25.08.04. Last revision was on 22.11. 06 The Euroclass system was introduced to harmonise standards across the EU. It categorises products into one of seven reaction to fire classes ranging from A1 (non-combustible) down to F (the worst performing class in terms of combustibility), using a defined test or combination of tests. EEA Euroclass A2-s1,d0 EN ISO 10848-2 & EN ISO 717-1 EN 12667 & ISO 8301 l = 0.036 W/m K 2.4 kg/m2 Dnfw 25 dB a w NRC 125 250 500 1000 2000 4000 Hz 0.90 0.85 0.40 0.80 0.90 0.85 1.00 1.00 a P Sound Absorption Class = A EN 13501-1 95% RH 1.0 0.8 0.6 0.4 0.2 0 125 250 500 1 000 2 000 4 000 a P Octave Band centre frequency (Hz) www.armstrong.fr/plafonds C – s2, d0 Difficult to ignite no/hardly limited drips/droplets A2 – s1, d1 B1 Difficult to ignite no drips/droplets B1 unlimited C – s3, d0 Difficult to ignite limited limited drips/droplets A2 – s2, d1 B1 Difficult to ignite limited drips/droplets B1 limited C – s2, d1 Difficult to ignite no/hardly many drips/droplets A2 – s1, d2 Burning droplets | d0, d1, d2 d0 = no droplets within 600 seconds d1 = droplet form within 600 seconds but do not burn for more than 10 seconds d2 = not as d0 or d1 Country Test standard Classification EC member states EN 13501-1 A2-s1,d0 | B-s1,d0 Switzerland Fire safety regulations BSV 2105 RF1 = non-flammable The reaction to fire classification system of ceiling products in Europe is based on the Euroclass system, defined by EN 13501-1. d0, d1 and d2, where d0 is the best.
wood-based panels - Swedish translation – Linguee
EN 13501-1. EN 12667. & ISO 8301 λ = 0.060 W/m K. 3.6 kg/m2. 99% RH. 85%. 30 YEAR system guarantee.
A2 - s3 d1. A2 - s1 d2. A2 - s2 d2. A2 - s3 d2. Combustible materials: Limited contribution to fire: B - s1 d0 Det finns främst två typer av brandklasser för brand i byggnad, se Bild 1: Brandklasser för byggprodukter, som används främst för ytmaterial på Lining class -/- A2-s1,d0 or A1. A2-s1,d0 see #04) B-s1,d0.